1 to 16 channels MS+ Systems with random configurable inputs

Klicken, um den Ordner zu erweitern oder zusammenzuziehen. Data Logger Summary
Klicken, um den Ordner zu erweitern oder zusammenzuziehen. Series MSx+, Datalogger / Datenrecorder (1 to 16 Channels)
Klicken, um den Ordner zu erweitern oder zusammenzuziehen. Series S Data Logger, 2 to 4 Channels
Temperature
Temperature/Humidity/Voltage
Voltage/Binary
Current/Binary
Temperature/Humidity
Communication/ Interface
Klicken, um den Ordner zu erweitern oder zusammenzuziehen. Handheld Measurement unit with Data Logger, Series Commeter, 2 bis 4 Kanäle
Klicken, um den Ordner zu erweitern oder zusammenzuziehen. HighSpeed Datenlogger
 

Features:

  • Random configurations possible, 1 to 16 inputs,   choice of 30 different input modules

  • Memory for 480.000 readings   Automatic downloading to PC if required

  • Communication via RS232, RS485,  modem or GSM modem

  • High system accuracy because of  16 bits A/D conversion

  • Easy installation and configuration  the system is virtually "plug & play"

  • Extensive alarm possibilities   audible, visual and via relay outputs

 General specifications

 




Go to Software
section


Go to Sensor
section

Material enclosure: 
No. of inputs


Operating limits 
Clock:
A/D conversion 
Sample rate:
Memory capacity: 
Recording methods:

Protection grade:
Sensor connection:



LED indicators:
(MS3+ / MS4+)



Mounting:
System requirements


Polycarbonate
16 free input slots, random configurable
(see list of available input modules)
0 to +50°C 
real-time clock
16 bits
selectable in fixed rates from 1 sec. to 24 hours
~480.000 analogue readings
- stop-when-full, 
- first-in-first-out
IP2x
- standard removable Wago connector
- sub-miniature thermocouple connector in 
  combination with a thermocouple input module

- mains power
- when exceeding alarm limits (2 per channel)
- when exceeding 75% of memory capacity
- when memory is full

ATM system will be supplied with wall brackets
Windows® 95/98/NT/2000/XP,  VGA color monitor, 10Mb harddisk space and 64Mb RAM recommended

The MS+  systems are stand-alone, modular, 1 to 16-channel data recorders. They can be completely configured according to your wishes. The basic unit has 16 free input slots and can be expanded with input modules. There is a choice from 30 different input modules, optical or non-optical isolated. When ordering, the desired configuration should be indicated. The systems are developed for stand-alone recording of temperature (using PT100, PT1000, Ni1000, and thermocouples), alternating current, AC voltage, DC process signals (mA, volt), pulses (status or counts), etc. Sensors with an output signal (e.g. for temperature, relative humidity or pressure sensing) can be easily connected to a mA or a volt input. 

The recorders have a large memory capacity for storage of 480,000 readings. They can operate independently, without a PC. Data can be stored in this memory using sampling intervals varying from 1x per second to 1x per 24 hours. The sampling interval selected will apply to all channels. It is possible to store the data on the hard disk of a PC during measuring and recording. The transfer of recorded data takes place via an RS-232 or RS-485 communication interface with the PC (or via a modem). The data stored on hard disk can be analyzed and printed using Windows ® software.

If there is a power failure, the recorder will stop collecting measured data. Until the moment of a power failure, the date and time of the failure will be stored in a backup battery, along with the recorded data. After the power has been restored, the ATM units will automatically resume their measurements.

Display, alarm and network (only for MS3+ and MS4+)

The actual readings of the various inputs are displayed on the convenient LCD screen on the ATM-03 and the ATM-04 units. All readings can be displayed one by one using the function keys. In addition, there are four LED’s to show the status of the power voltage and the memory (exceeding 75% and 100% full). These status indicators are also announced by a sound signal.

The MS3+ and MS4+ units have extensive features for alarm signaling. Each input has 2 independently adjustable alarm set points with adjustable hysteretic and time delay.

An alarm is announced both audibly (buzzer) and visually (LED 1 to 32). The MS3+ has 1 relay, and the MS4+ unit has 16 relays, available to send signals to a central signaling system or to activate a telephone dialer. In addition, multiple MS+ units can be networked via an RS485 interface.

 

 MS2+ 1 to 16 channel recorder

Size:
Weight:
Communication:
Display:
Alarm signalling:
Alarm output:
Network:

220 x 180 x 90mm (w x h x d)
800gr.
RS232
-
-
-
-

Order No.

Model

Daten-Recorder Decription

Manual

W07-100-100 M0002-MS2+ Data Recorder / Logger unit Basic Handuch für MS-2+, MS-3+ und MS-4+, Appendix zum Basis Handbuch Serie MS2+, MS3+ und MS4+

 MS3+ 1 to 16 channel recorder  LCD display + alarm (Trigger-Function) (1 relay output  )

Size:


Weight:
Communication:
Display:
Alarm signalling:

Alarm output:
 

220 x 180 x 90mm (w x h x d)
size when using thermoouple input modules:
250 x 320 x 110mm (w x h x d)
800gr.
RS232 and RS485
2-row alpha numeric LCD
- optical (2 LEDs per channel)
- audible (built-in buzzer)
1 relay contact (230VAC/6A)

 

Order No.

Model

Daten-Recorder Decription

Manual

W07-100-110 M0002-MS3+ Data Recorder / Logger unit Basic Handuch für MS-2+, MS-3+ und MS-4+, Appendix zum Basis Handbuch Serie MS2+, MS3+ und MS4+

MS4+ 1 to 16 channel recorder  LCD display + alarm (16 relay outputs) + network

Size:
Weight:
Communication:
Display:
Alarm signalling:

Alarm output:
Network:

 

250 x 320 x 110mm (w x h x d)
2000gr.
RS232 and RS485
2-row alpha numeric LCD
- optical (2 LEDs per channel)
- audible (built-in buzzer)
1 relay contact (230VAC/6A)
multiple units can be daisy chained via RS485 interface

Order No.

Model

Daten-Recorder Decription

Manual

W07-100-120 M0002-MS4+ Data Recorder / Logger unit Basic Handuch für MS-2+, MS-3+ und MS-4+, Appendix zum Basis Handbuch Serie MS2+, MS3+ und MS4+

Overview input modules  (random configurations possible)

Input module A0 4 to 20mA

Input module A0 4 to 20mA

Counter input module CTU

Counter input module CTU


Opened MS3+ with 14 installed input modules

Opened MS3+ with 14 installed input modules

Order No.

Model

Measured value

Accurycy

Note

DC-Current-Module without galvanic isolation

W07-100-150 M1001-A0 dc current 4 to 20 mA ±0.1% FS

With source approximately 21V for two-wire transducers with current loop (e.g. temperature and humidity transducers Comet). Only galvanic not isolated.

W07-100-160 M1002-A1 dc current 4 to 20 mA ±0.1% FS

for passive sensing of current

W07-100-170 M1002-B0 DC current 0 to 20mA ±0.1% FS without galvanic isolation
W07-100-180 M1002-B1 DC current 0 to 1A ±0.1% FS
W07-100-190 M1002-B2 DC current 0 to 5A ±0.1% FS

DC-Current-Module with galvanic isolation

W07-100-165 M1025-A1G DC current 4 to 20mA ±0.1% FS

galvanic isolated

W07-100-175 M1026-B0G DC current 0 to 20mA ±0.1% FS
W07-100-185 M1027-B1G DC current 0 to 1A ±0.1% FS
W07-100-195 M1028-B2G DC current 0 to 5A ±0.1% FS

AC-Current-Module with galvanic isolation

W07-100-196 M1006-C0G DC current 0 to 20mA ±1% FS

galvanic isolated

W07-100-206 M1007-C1G DC current 0 to 1A ±1% FS
W07-100-200 M1008-C2G DC current 0 to 5A ±1% FS

DC-Voltage-Module without galvanic isolation

W07-100-215 M1009-D0 DC voltage  to 100mV ±0,1% FS without galvanic isolation

 

W07-100-225 M1010-D1 DC voltage 0 to 1V ±0,1% FS
W07-100-235 M1011-D2 DC voltage 0 to 10V ±0,1% FS
W07-100-245 M1012-D3 DC voltage 0 to 400V ±0,1% FS

DC-Voltage-Module with galvanic isolation

W07-100-210 M1029-D0G DC voltage  to 100mV ±0,1% FS

galvanic isolated

W07-100-220 M1030-D1G DC voltage 0 to 1V ±0,1% FS
W07-100-230 M1031-D2G DC voltage 0 to 10V ±0,1% FS
W07-100-240 M1032-D3G DC voltage 0 to 400V ±0,1% FS

AC-Voltages-Module with galvanic isolation

W07-100-250 M1013-E0 AC voltage  to 100mV ±0,1% FS

galvanic isolated

W07-100-260 M1014-E1 AC voltage 0 to 1V ±0,1% FS
W07-100-270 M1015-E2 AC voltage 0 to 10V ±0,1% FS
W07-100-280 M1016-E3 AC voltage 0 to 400V ±0,1% FS

Resitor-Module without galvanic isolation

W07-100-300 M1017-F measurement of resistance (specify the range) ±0.1% FS

two-wire connection

Resistor-Module with galvanic isolation

W07-100-305 M1017-FG measurement of resistance (specify the range) ±0.1% FS

two-wire connection galvanic isolated

Temperature-Module for Ni1000, Pt100 and Pt1000 without galvanic isolation

W07-100-310 M1018-J input for Nickel RTD temperature sensor Ni1000, 6180 ppm/°C, range -50 to +250°C -50°C to +100°C ±0.2°C
100°C to 250°C ±0.2%
from reading

without galvanic isolation

W07-100-320 M1019-K input for Platinum RTD temperature sensor Pt100, range -140 to +600°C -140°C to +100°C ±0.2°C
100°c to 600°C ±0.2%
from reading
two-wire connection without galvanic isolation
W07-100-330 M1020-K1 input for Platinum RTD temperature sensor Pt1000, range -140 to +600°C -140°C to +100°C ±0.2°C
100°c to 600°C ±0.2%
from reading

Temperature-Module for Ni1000, Pt100 and Pt1000 with galvanic isolation

W07-100-340 M1034-JG input for Nickel RTD temperature sensor Ni1000, 6180 ppm/°C, range -50 to +250°C -50°C to +100°C ±0.2°C
100°C to 250°C ±0.2%
from reading

without galvanic isolation

W07-100-350 M1035-KG input for Platinum RTD temperature sensor Pt100, range -140 to +600°C -140°C to +100°C ±0.2°C
100°c to 600°C ±0.2%
from reading
two-wire connection with galvanic isolation
W07-100-360 M1036-K1G input for Platinum RTD temperature sensor Pt1000, range -140 to +600°C -140°C to +100°C ±0.2°C
100°c to 600°C ±0.2%
from reading

Temperature-Module for Thermocouple Type K, J. S und B without galvanic isolation

W07-100-410 M1021-N thermocouple K (NiCr-Ni) range -70 to +1300°C ±(0.3% + 1°C) from reading

linearized, cold junction compensation .without galvanic isolation

W07-100-420 M1022-O thermocouple J (Fe-Co) range -200 to 750°C ±(0.3% + 1°C)from reading
W07-100-430 M1023-P thermocouple S (Pt10%Rh-Pt), range 0 to 1700°C ±(0.3% + 1°C) from reading
W07-100-440 M1024-Q thermocouple B (Pt30%Rh-Pt), range +100 to +1800°C ±(0.3% + 1°C) from reading

Temperature-Module for Thermocouple Type K, J. S und B with galvanic isolation

W07-100-415 M1037-NG thermocouple K (NiCr-Ni) range -70 to +1300°C ±(0.3% + 1°C) from reading

linearized, cold junction compensation .with galvanic isolation.

W07-100-425 M1004-OG thermocouple J (Fe-Co) range -200 to 750°C ±(0.3% + 1°C)from reading
W07-100-435 M1039-PG thermocouple S (Pt10%Rh-Pt), range 0 to 1700°C ±(0.3% + 1°C) from reading
W07-100-445 M1040-QG thermocouple B (Pt30%Rh-Pt), range +100 to +1800°C ±(0.3% + 1°C) from reading

Binary-Input Module

W07-100-450 M1041-S

binary input for potential-less contacts. Maximum resistance of closed contact: 1000 ohms minimum duration for recording: 200ms

W07-100-460 M1042-S1

binary voltage input. Voltage for "switched ON" state: 3 to 30Vdc, input current in the"switched ON" state: 1 to 9mA-depending on the applied voltage, minimum duration for indication of change: 200ms, galvanic isolated

Counter-Module

W07-100-500 M1044-CTU

counter input for voltage signal. Voltage for "HIGH" state (for counter status change): 3 to 24Vdc maximum pulse frequency 5kHz, backed-up operation, galvanic isolated

W07-100-510 M1042-CTK

counter input for potential-less contacts and open collector.  Maximum pulse frequency 5kHz, programmable filter of pulse ringing, backed-up operation during power mains failure, maximum resistance of closed contact: 10 kohms minimum resistance of open contact: 250 kohms, galvanic unisolated

Frequency -Counter Modue

W07-100-550 M1047-FU

input for measurement of frequency of voltage. Signal 0 to 5kHz, resolution 1Hz, accuracy ±(0.2% from reading + 1Hz) input voltage for state "H": 3 to 24Vdc input current in state "H": approximately 7mA minimum duration of input impuls: 30us, galvanic isolated

W07-100-560 M1048-FK

input for measurement of frequency of contact switching. 0 to 5kHz, resolution 1Hz, accuracy ±(0.2% from reading + 1Hz) maximum resistance of closed contact: 10 kohms minimum resistance of open contact: 250 kohms, minimum duration of input pulse: 30us, galvanic unisolated

Input for serial signal RS485 for devices upporting Advantech protocole

W07-100-550 M104-RS

input for serial signal RS485 for devices supporting Advantech protocole. E.g. measurement from transmitters with RS485 digital output connected to the serial RS485 network - ADAM Advantech protocol , galvanic isolated 

 

Probes for Data-Loggers / Data recorders Series MS+

Pt1000 temperature probe

Pt1000 temperature probe

Temperature Probes with Pt1000 3850ppm Sensors for Data Loggers Series MS+

Order No.

Model Description Data sheet
W14-100-xxx   Pt1000 3850ppm Probes

Temperature Transducers with 4 - 20mA output for Data-Loggers / Data recorders Series MS+

Photo of temperature transmitter Indoor and Outdoor Temperature Transducers with 4 -20mA output

Order No.

Model Description Data sheet
x P41xx Indoor Temperature Transducers with 4 -20mA output Data Sheet Transducers Series PManual about Transducers Series P
x P01xx Outdoor Temperature Transducers with 4 -20mA output