MS2+ 1
to 16 channel recorder |
|
 |
Size:
Weight:
Communication:
Display:
Alarm signalling:
Alarm output:
Network: |
220 x
180 x 90mm (w x h x d)
800gr.
RS232
-
-
-
- |
|
Order No. |
Model |
Daten-Recorder Decription |
Manual |
| W07-100-100 |
M0002-MS2+ |
Data Recorder / Logger
unit |
  |
|
MS3+
1
to 16 channel recorder LCD
display + alarm
(Trigger-Function)
(1 relay output
) |
|
 |
Size:
Weight:
Communication:
Display:
Alarm signalling:
Alarm output:
|
220 x
180 x 90mm (w x h x d)
size when using thermoouple input modules:
250 x 320 x 110mm (w x h x d)
800gr.
RS232 and RS485
2-row alpha numeric LCD
- optical (2 LEDs per channel)
- audible (built-in buzzer)
1 relay contact (230VAC/6A)
|
|
Order No. |
Model |
Daten-Recorder Decription |
Manual |
| W07-100-110 |
M0002-MS3+ |
Data Recorder / Logger unit |
  |
|
MS4+ 1
to 16 channel recorder LCD display + alarm (16 relay outputs) + network |
|
 |
Size:
Weight:
Communication:
Display:
Alarm signalling:
Alarm output:
Network:
|
250 x
320 x 110mm (w x h x d)
2000gr.
RS232 and RS485
2-row alpha numeric LCD
- optical (2 LEDs per channel)
- audible (built-in buzzer)
1 relay contact (230VAC/6A)
multiple units can be daisy chained via RS485 interface |
|
Order No. |
Model |
Daten-Recorder Decription |
Manual |
| W07-100-120 |
M0002-MS4+ |
Data Recorder / Logger unit |
  |
|
Overview
input modules
(random configurations possible) |
|

Input module
A0 4 to 20mA
|

|

Opened MS3+ with 14 installed input
modules
|
|
Order No. |
Model |
Measured value |
Accurycy |
Note |
|
DC-Current-Module without galvanic isolation
|
| W07-100-150 |
M1001-A0 |
dc
current 4 to 20 mA |
±0.1% FS |
With source approximately
21V for two-wire transducers with current loop (e.g. temperature and
humidity transducers Comet). Only galvanic not isolated. |
| W07-100-160 |
M1002-A1 |
dc current 4 to
20 mA |
±0.1% FS
|
for passive sensing of
current |
| W07-100-170 |
M1002-B0 |
DC current 0 to
20mA |
±0.1% FS
|
without galvanic isolation |
| W07-100-180 |
M1002-B1 |
DC current 0 to
1A |
±0.1% FS
|
| W07-100-190 |
M1002-B2 |
DC current 0 to
5A |
±0.1% FS
|
|
DC-Current-Module with galvanic isolation
|
| W07-100-165 |
M1025-A1G |
DC
current 4 to 20mA |
±0.1% FS
|
galvanic isolated |
| W07-100-175 |
M1026-B0G |
DC
current 0 to 20mA |
±0.1% FS
|
| W07-100-185 |
M1027-B1G |
DC
current 0 to 1A |
±0.1% FS
|
| W07-100-195 |
M1028-B2G |
DC
current 0 to 5A |
±0.1% FS
|
|
AC-Current-Module with galvanic
isolation |
| W07-100-196 |
M1006-C0G |
DC
current 0 to 20mA |
±1% FS
|
galvanic isolated |
| W07-100-206 |
M1007-C1G |
DC
current 0 to 1A |
±1% FS
|
| W07-100-200 |
M1008-C2G |
DC
current 0 to 5A |
±1% FS
|
|
DC-Voltage-Module without galvanic isolation
|
| W07-100-215 |
M1009-D0 |
DC
voltage to 100mV |
±0,1% FS
|
without galvanic isolation
|
| W07-100-225 |
M1010-D1 |
DC
voltage 0 to 1V |
±0,1% FS
|
| W07-100-235 |
M1011-D2 |
DC
voltage 0 to 10V |
±0,1% FS
|
| W07-100-245 |
M1012-D3 |
DC
voltage 0 to 400V |
±0,1% FS
|
|
DC-Voltage-Module with galvanic isolation
|
| W07-100-210 |
M1029-D0G |
DC
voltage to 100mV |
±0,1% FS
|
galvanic isolated |
| W07-100-220 |
M1030-D1G |
DC
voltage 0 to 1V |
±0,1% FS
|
| W07-100-230 |
M1031-D2G |
DC
voltage 0 to 10V |
±0,1% FS
|
| W07-100-240 |
M1032-D3G |
DC
voltage 0 to 400V |
±0,1% FS
|
|
AC-Voltages-Module with galvanic isolation
|
| W07-100-250 |
M1013-E0 |
AC
voltage to 100mV |
±0,1% FS
|
galvanic isolated |
| W07-100-260 |
M1014-E1 |
AC
voltage 0 to 1V |
±0,1% FS
|
| W07-100-270 |
M1015-E2 |
AC
voltage 0 to 10V |
±0,1% FS
|
| W07-100-280 |
M1016-E3 |
AC
voltage 0 to 400V |
±0,1% FS
|
|
Resitor-Module
without galvanic isolation |
| W07-100-300 |
M1017-F |
measurement of resistance (specify the range) |
±0.1% FS
|
two-wire connection |
|
Resistor-Module
with galvanic isolation |
| W07-100-305 |
M1017-FG |
measurement of resistance (specify
the range) |
±0.1% FS
|
two-wire connection
galvanic isolated |
|
Temperature-Module for Ni1000, Pt100
and Pt1000 without galvanic isolation |
| W07-100-310 |
M1018-J |
input for Nickel RTD temperature sensor Ni1000, 6180 ppm/°C, range -50
to +250°C |
-50°C
to +100°C
±0.2°C
100°C to 250°C ±0.2%
from reading
|
without galvanic isolation |
| W07-100-320 |
M1019-K |
input for Platinum RTD temperature sensor Pt100, range -140 to +600°C
|
-140°C to +100°C
±0.2°C
100°c to 600°C ±0.2%
from reading
|
two-wire connection
without galvanic isolation |
| W07-100-330 |
M1020-K1 |
input for Platinum RTD temperature sensor Pt1000, range -140 to +600°C
|
-140°C to +100°C ±0.2°C
100°c to 600°C ±0.2%
from reading
|
|
Temperature-Module for Ni1000, Pt100
and Pt1000 with galvanic isolation |
| W07-100-340 |
M1034-JG |
input for Nickel RTD temperature sensor Ni1000, 6180 ppm/°C, range -50
to +250°C |
-50°C to +100°C
±0.2°C
100°C to 250°C ±0.2%
from reading |
without galvanic
isolation |
| W07-100-350 |
M1035-KG |
input for Platinum RTD temperature sensor Pt100, range -140 to +600°C
|
-140°C to +100°C
±0.2°C
100°c to 600°C ±0.2%
from reading |
two-wire connection
with galvanic isolation |
| W07-100-360 |
M1036-K1G |
input for Platinum RTD temperature sensor Pt1000, range -140 to +600°C
|
-140°C to +100°C ±0.2°C
100°c to 600°C ±0.2%
from reading |
|
Temperature-Module for Thermocouple Type K, J. S
und B
without galvanic isolation |
| W07-100-410 |
M1021-N |
thermocouple K (NiCr-Ni) range -70 to +1300°C |
±(0.3% + 1°C)
from reading |
linearized, cold junction
compensation .without galvanic isolation |
| W07-100-420 |
M1022-O |
thermocouple J (Fe-Co) range -200 to 750°C |
±(0.3% + 1°C)from
reading |
| W07-100-430 |
M1023-P |
thermocouple S (Pt10%Rh-Pt), range 0 to 1700°C |
±(0.3% + 1°C)
from reading |
| W07-100-440 |
M1024-Q |
thermocouple B (Pt30%Rh-Pt), range +100 to +1800°C |
±(0.3% + 1°C)
from reading |
|
Temperature-Module for Thermocouple Type K, J. S
und B
with galvanic isolation |
| W07-100-415 |
M1037-NG |
thermocouple K (NiCr-Ni) range -70 to +1300°C |
±(0.3% + 1°C)
from reading |
linearized, cold junction compensation .with
galvanic isolation. |
| W07-100-425 |
M1004-OG |
thermocouple J (Fe-Co) range -200 to 750°C |
±(0.3% + 1°C)from
reading |
| W07-100-435 |
M1039-PG |
thermocouple S (Pt10%Rh-Pt), range 0 to 1700°C |
±(0.3% + 1°C)
from reading |
| W07-100-445 |
M1040-QG |
thermocouple B (Pt30%Rh-Pt), range +100 to +1800°C |
±(0.3% + 1°C)
from reading |
|
Binary-Input Module |
| W07-100-450 |
M1041-S |
binary input for
potential-less contacts. Maximum resistance of closed contact: 1000 ohms
minimum duration for recording: 200ms |
| W07-100-460 |
M1042-S1 |
binary voltage input.
Voltage for "switched ON" state: 3 to 30Vdc, input current in
the"switched ON" state: 1 to 9mA-depending on the applied voltage,
minimum duration for indication of change: 200ms, galvanic isolated
|
|
Counter-Module |
| W07-100-500 |
M1044-CTU |
counter input for voltage
signal. Voltage for "HIGH" state (for counter status change): 3 to 24Vdc
maximum pulse frequency 5kHz, backed-up operation, galvanic isolated |
| W07-100-510 |
M1042-CTK |
counter input for potential-less contacts
and open collector. Maximum pulse frequency 5kHz, programmable
filter of pulse ringing, backed-up operation during power mains failure,
maximum resistance of closed contact: 10 kohms minimum resistance of
open contact: 250 kohms, galvanic unisolated |
|
Frequency -Counter Modue |
| W07-100-550 |
M1047-FU |
input for measurement of
frequency of voltage. Signal 0 to 5kHz, resolution 1Hz, accuracy ±(0.2%
from reading + 1Hz) input voltage for state "H": 3 to 24Vdc input
current in state "H": approximately 7mA minimum duration of input impuls:
30us, galvanic isolated |
| W07-100-560 |
M1048-FK |
input for measurement of frequency of
contact switching. 0 to 5kHz, resolution 1Hz, accuracy ±(0.2% from
reading + 1Hz) maximum resistance of closed contact: 10 kohms minimum
resistance of open contact: 250 kohms, minimum duration of input pulse:
30us, galvanic unisolated |
|
Input for serial signal RS485 for devices upporting Advantech protocole |
| W07-100-550 |
M104-RS |
input for serial signal
RS485 for devices supporting Advantech protocole. E.g. measurement from
transmitters with RS485 digital output connected to the serial RS485
network - ADAM Advantech protocol , galvanic isolated |